Version Description

This component continues to evolve based on the Kubernetes community node-problem-detector v0.8.2 version, rather than directly following subsequent community versions or the master branch. GPU/DCU-related capabilities are independently developed and evolved by the TKE team. The main differences from the community version are listed in the following table.
Difference
Community v0.8.2 / master Branch
This Component (TKE Edition)
GPU detection
No NVML active polling capability (also not introduced in the master branch)
Added gpuMonitor (actively polls temperature/power/ECC/NVLink/PCIe and other metrics through NVML) and xidMonitor (parses NVIDIA XID logs)
Hygon DCU detection
Not supported.
Added dcuMonitor (actively polls through hy-smi) and dcuXidMonitor/dcuSxidMonitor (parses Hygon XID/SXID logs)
Zombie process detection
Not supported
Added zombieprocessmonitor
Stuck/hung process detection
Not supported.
Added stuck_process_monitor (detects D/T states, with self-exemption and secondary confirmation to filter transient jitter)
Disk read-only detection
Not supported.
Added diskromonitor and disk-ro-check detection items
kubelet root-dir drift detection
Not supported.
Added kubelet_rootdir_check
Health check for Docker/Containerd/Kubelet components
Only kubelet and docker are supported.
Extended support for independent health checks of containerd and CRI
Log counting-based detection (frequent restarts/connection exceptions, and more)
Not supported
Added log-counter series detection items (FrequentKubeletRestart, ConnectApiServer, PLEGNotHealthy, and others)
Windows support
Supported
Not supported (this component only caters to Linux nodes, and Windows-related adaptation code has been removed).

Introduction

Component Description

Node-Problem-Detector-Plus is a health monitoring component for Kubernetes cluster nodes. It runs as a DaemonSet in TKE environments, helping users detect various node anomalies in real time and report the detection results to the upstream kube-apiserver.
The supported anomaly types include OS-level anomalies (kernel deadlock, read-only file system, OOM, and so on), container runtime anomalies (frequent Docker/Containerd restarts), NVIDIA GPU hardware failures, and Hygon DCU device failures (card dropout, high temperature, ECC errors, HySwitch anomalies, and so on).

Kubernetes Objects Deployed in a Cluster

Kubernetes Object Name
Type
Resource Capacity
Namespaces
node-problem-detector
DaemonSet
0.5C512M
kube-system
node-problem-detector
ServiceAccount
-
kube-system
node-problem-detector
ClusterRole
-
-
node-problem-detector
ClusterRoleBinding
-
-

Scenarios

You can use the Node-Problem-Detector-Plus component to monitor node health, including metrics such as kernel deadlock, OOM, system thread quantity pressure, and system file descriptor pressure. The component reports these metrics to the apiserver in the form of Node Conditions and Events.
You can detect the corresponding metrics to predict node resource pressure in advance. Before the node starts evicting Pods, you can manually release or scale out node resources to prevent potential losses caused by Kubernetes resource reclamation or node unavailability.
For GPU/DCU heterogeneous compute nodes, NPD can also proactively detect hardware failures (such as device loss, high temperature, and ECC errors) and report them through Node Conditions, allowing the Ops team to identify and handle faulty devices in a timely manner.

Limits

To use NPD in a cluster, you need to install the extension component in the cluster. The NPD container resource Limits are 0.5 CPU cores and 512 MB of memory, and the resource Requests are 0.1 CPU cores and 200 MB of memory.

Component Permission Description

Permission Description

The permissions for this component represent the minimum set of permissions required to implement the current feature.

Permission Scenarios

Function
Object Involved
Operation Permission Involved
Need to listen for node list changes, report fault information when a node encounters a failure, and modify the node condition.
nodes,nodes/status
get/list/watch,patch
Send events to notify the cluster.
event
create/patch/update
To detect ghost containers and similar scenarios, obtain the list of Pods on the node.
pods
list

Permission Definitions

rules:
- apiGroups:
- ""
resources:
- nodes
verbs:
- get
- list
- watch
- apiGroups:
- ""
resources:
- nodes/status
verbs:
- patch
- apiGroups:
- ""
resources:
- events
verbs:
- create
- patch
- update
- apiGroups:
- ""
resources:
- pods
verbs:
- list

Usage

1. Log in to the TKE console. In the left sidebar, choose Clusters.
2. In the cluster list, click the target cluster ID to go to the cluster details page.
3. In the left sidebar, choose Component Management. On the displayed page, click Create.
4. On the Create Component page, select Node-Problem-Detector-Plus.
5. Click Done to create the component. After the component is installed, a corresponding node-problem-detector resource will be available in your cluster, and corresponding entries will be added to the Node Conditions.

Check Item Description

NPD has multiple built-in detectors, which are divided into 6 categories by detection target. Each category of detectors can be individually enabled or disabled in the component's advanced configuration.

System Kernel Check

Check Item
Detection Target
Detection Method
Trigger Condition
Corresponding Condition
Kernel deadlock detection
Whether Docker/AUFS-related kernel tasks are blocked.
Parse task blocking information in kernel logs (/dev/kmsg).
Detected that a task has been blocked for longer than the configured duration.
KernelDeadlock
File system read-only detection
Whether the root file system is passively remounted as read-only.
Parse remount events in kernel logs.
Detected that the kernel proactively remounted the file system as read-only.
ReadonlyFilesystem
Disk read-only detection
Whether specified mount points (/, /data) become read-only.
Actively attempt to write a test file.
Multiple consecutive write failures
DiskReadOnly
XFS metadata error detection
Whether metadata I/O errors occur on the XFS file system.
Parse XFS error information in kernel logs.
Detected XFS metadata I/O error logs.
XFSError
OOM event detection
Whether a process or Pod is killed by the system OOM Killer.
Parse OOM Killer records in kernel logs.
Detected logs of processes/Pods being killed.
None (only generates an Event and does not generate a Condition)
D state process detection
Whether there are processes that remain in uninterruptible sleep (D state) for a long time.
Periodically scan system process states, exclude NPD processes and their spawned plugin subprocesses, count candidate processes only if they remain in the target state for two consecutive samples at an interval of 500 ms, and avoid false positives caused by transient disk jitter.
Detected that a process has been in the D state for more than 120 seconds.
StuckProcess
Hung process detection
Whether there are processes suspended by SIGSTOP (T state).
Periodically scan system process states, with exclusion rules consistent with those for D state process detection.
Detected that a process has been in the T state for more than 120 seconds.
StoppedProcess
Ext4/IO error detection
Whether the file system has Ext4 errors or Buffer I/O errors.
Parse kernel logs.
Detected corresponding error logs.
None (only generates an Event and does not generate a Condition)

Container Runtime and Kubelet Check

Check Item
Detection Target
Detection Method
Trigger Condition
Corresponding Condition
Docker Overlay2 corruption detection
Whether the Docker overlay2 storage layer is corrupted.
Parse readlink errors in dockerd logs.
Detected abnormal logs for storage layer reads.
CorruptDockerOverlay2
Service running status detection
Whether kubelet/Docker/Containerd system services are in the running state.
Query service status through systemd.
The service is in a non-running state.
KubeletProblem,DockerdProblem,ContainerdProblem
Service health check
Whether kubelet/Docker/Containerd/CRI can normally respond to health check requests.
Call component health check APIs periodically.
Consecutive health check failures
KubeletUnhealthy,ContainerRuntimeUnhealthy,ContainerdRuntimeUnhealthy,ContainerRuntimeInterfaceUnhealthy
Frequent service restart detection
Whether kubelet/Docker/Containerd restart frequently.
Count the occurrences of service startup logs within a time window.
The number of restarts reaches 5 within 20 minutes.
FrequentKubeletRestart,FrequentDockerRestart,FrequentContainerdRestart
Ghost container detection
Whether ghost containers whose corresponding processes no longer exist in the container runtime records exist.
Periodically scan container runtime states and compare them with actual processes.
Ghost container detected.
HasGhostContainer
API Server connection detection
Whether the connection between kubelet and API Server is normal.
Count the occurrences of connection exceptions in kubelet logs.
The number of connection exceptions within a time window reaches the threshold.
ConnectApiServer
PLEG health check
Whether the kubelet Pod Lifecycle Event Generator (PLEG) is healthy.
Count the occurrences of PLEG exceptions in kubelet logs.
The number of exceptions within a time window reaches the threshold.
PLEGNotHealthy
kubelet root directory drift detection
Whether existing running Pods still mount volumes from the old path after kubelet modifies the root-dir configuration.
Periodically scan the volume mount paths of containers on nodes to determine whether multiple different root-dir prefixes exist.
Detected two or more different root-dir prefixes.
KubeletRootDirMismatch

System Resource Check

Check Item
Detection Target
Detection Method
Default Threshold
Corresponding Condition
File descriptor pressure detection
Host file descriptor utilization
Read system file descriptor usage.
Utilization reaches 80% of the maximum value.
FDPressure,FDProblem
PID pressure detection
Node PID resource utilization
Read system PID usage.
Utilization reaches 90% of the maximum value.
CustomPIDPressure
Thread quantity pressure detection
System thread quantity utilization
Read system thread quantity usage.
Utilization reaches 90% of the maximum value.
ThreadPressure
Conntrack table pressure detection
conntrack connection tracking table utilization
Read system conntrack table usage.
Utilization reaches 90%.
ConntrackProblem
Disk utilization detection (Overlay)
Container storage disk (/data) utilization
Read disk usage.
Utilization reaches 80%.
OverlayDiskPressure
Detection of the number of processes in persistent D state
Number of processes on the entire machine that remain in uninterruptible sleep (D state)
Periodically scan the process states of the entire machine, count the number of processes that remain in the D state for two consecutive samples, and exclude NPD processes and their spawned plugin subprocesses.
The number exceeds 10.
ProcessProblem
System load detection
System 5-minute average load
Read system load average.
Exceeds the preset threshold
SystemLoadProblem
Network device detection
Whether the network device is down or frequently unregistered
Read network device status and parse NIC unregister records in kernel logs.
Device exception or frequent unregister detected
NetDeviceProblem,FrequentUnregisterNetDevice
MTU cache detection
Whether the route MTU cache is expired
Read route cache information.
Cache expired
MtuCacheProblem
TCP timestamp detection
Whether the net.ipv4.tcp_timestamps kernel parameter is disabled
Read system kernel parameters.
The parameter is disabled.
NetIpv4TcpTimeStampProblem

Service Health Check

Check Item
Detection Target
Detection Method
Default Interval
Corresponding Condition
NTP time synchronization check
Whether the ntpd/chronyd/systemd-timesyncd time synchronization service is running
Query service status through systemd.
1 minute
NTPProblem

GPU (NVIDIA) Hardware Check

NPD proactively polls GPU hardware counters through the official NVIDIA NVML library and parses NVIDIA XID error codes in system logs, providing dual-channel detection of GPU hardware issues.
Proactive Polling Detection:
Check Item
Detection Method
Default Threshold
Default Detection Interval
Corresponding Condition
GPU temperature detection
Read the GPU temperature counter.
Exceeds 85℃
15 seconds
GPUTempError
GPU power detection
Read GPU power utilization.
Exceeds 120%
15 seconds
GPUPowerError
NVLink detection
Read the NVLink CRC error increment.
More than 10 new errors are detected within a detection period.
60 seconds
GPUNvlinkError
ECC mode detection
Compare whether the current ECC mode is consistent with the ECC mode to be applied.
Mismatch
30 seconds
GPUEccModeError
GPU device loss detection
Calculate the difference between the healthy GPU quantity and the initial quantity.
Device quantity decreases.
5 (seconds)
GPUDeviceLost
InfoROM integrity detection
Read the InfoROM checksum.
Checksum error
60 seconds
GPUInfoROMCorrupted
Row remapping detection
Read the memory row remapping count.
Correctable rows exceed 10 or uncorrectable rows increase.
30 seconds
GPURemappingRowsError
Pending retired page detection
Read the pending memory retired page information.
Pending retired pages exist.
30 seconds
GPUPendingRetiredPages
Double-bit ECC error detection
Read the memory double-bit (uncorrectable) ECC error count increment.
Any new error is detected.
30 seconds
GPUDoubleBitEccError
Single-bit ECC error rate detection
Count the single-bit (correctable) ECC error increment within the detection period.
More than 30 new errors are detected within a detection period.
30 seconds
GPUHighSingleBitEccError
PCIe link detection
Read the PCIe link status between the GPU and the host.
Link error
30 seconds
GPUPCIeError
Note:
GPUDeviceLost, GPUInfoROMCorrupted, GPURemappingRowsError, GPUPendingRetiredPages, GPUDoubleBitEccError, GPUHighSingleBitEccError, and GPUPCIeError are permanent alarms. Once triggered, they do not automatically recover to False. You need to manually check the hardware status and restart the NPD component to clear these alarms. Other detection items recover automatically after the fault is resolved.
NVIDIA XID Log Detection:
xidMonitor parses records in the GPU system log (/var/log/messages) that match the pattern NVRM: Xid (PCI:xxx): <error code>, <description>, and classifies them into five categories based on the error code set: fatal, warning, application-level, ignore, and fallback. The same Condition/Event may correspond to multiple error codes:
Check Item
Detection Target
Detection Method
Trigger Condition
Corresponding Condition
GPU fatal XID detection
GPU hardware-level fatal error
Parse XID error codes in GPU system logs and match them against the fatal error code set.
Detected either XID 74 (NVLink error) or 79 (GPU dropped off the PCIe bus).
GPUXIDFatalError
GPU warning XID detection
GPU hardware-level warning faults (ECC errors, context switch timeout, firmware communication exceptions, and so on)
Parse XID error codes in GPU system logs and match them against the warning error code set.
Detected any of XID 48 (double-bit uncorrectable ECC error in video memory), 92 (high single-bit ECC error rate), 95 (uncontrollable ECC error), 63 (ECC page retirement/row remapping record event), 94 (controllable ECC error isolation after row remapping failure), 137 (uncorrectable NVLink error), 140 (unrecovered ECC error), 13 (graphics engine exception), 31 (video memory page fault), 43 (GPU stopped processing), 45 (preemptive cleanup triggered by preceding error), 62 (internal microcontroller stopped running), 68 (video decode engine exception), 109 (context switch timeout), 110 (security fault), 119 (GSP RPC call timeout), 120 (GSP firmware internal error), or 122/123/124 (firmware SPI bus read/write/erase failure).
GPUXIDWarningError
GPU application-level XID detection
GPU exceptions triggered by applications (out-of-bounds video memory access, ECC recording failures, and so on)
Parse XID error codes in GPU system logs and match them against the application-level error code set.
Detected any of XID 13, 31, 43, 45, 63, 68, 94 (also classified as warning-level, which triggers an Event and sets GPUXIDWarningError to True) or 64 (application-level only, which triggers an Event but does not affect the node Condition).
None (only generates Event: DeviceHasApplicationXidError)
GPU ignored XID detection
Known benign events
Discard the error directly after matching the ignore error code set, and do not generate log parsing results.
Detected XID 141.
None (no alarms or events are generated)
GPU other XID detection
New error codes not classified into any of the above categories
Parse XID error codes in GPU system logs, and perform fallback capture when none of the above error code sets are matched.
Detected any XID error code other than those listed above.
None (only generates Event: DeviceHasOtherXidError)
Note:
The fatal and warning categories are permanent rules. Once triggered, the corresponding Condition is set to True and retained for a long time. You must restart the NPD component to clear it. The application-level and fallback categories are temporary rules. They only generate one-time Events and are not reflected in node Conditions. The ignore category directly discards hits without generating any alarms or events.

Hygon DCU Hardware Check

NPD proactively polls DCU hardware counters through Hygon's official management tool hy-smi and parses Hygon XID/SXID error codes in system logs, providing dual-channel detection of DCU hardware issues. To use this capability, the node must have the Hygon DCU driver and the hy-smi management tool installed.
Proactive Polling Detection:
Check Item
Detection Method
Default Threshold
Default Detection Interval
Corresponding Condition
DCU temperature detection
Read the DCU temperature sensor (highest temperature point).
Exceeds 90℃
15 seconds
HygonDCUHighTemp
DCU ECC error detection
Read ECC error counts of each DCU hardware module.
Any increase in uncorrectable errors, or an increase of more than 30 correctable errors within a detection period, or a single-bit error rate exceeding the threshold.
30 seconds
HygonDCUUncorrectableErr,HygonDCUHighSBERate
HSL interconnect detection
Read the high-speed interconnect (HSL) link status between DCUs.
More than 10 new CRC errors are detected within a detection period.
60 seconds
HygonHySwitchError
PCIe link detection
Read the PCIe link status between the DCU and the host.
Link degradation or loss
30 seconds
HygonDCUPCIeLinkLost
Hygon DCU XID Log Detection:
dcuXidMonitor parses records in Hygon DCU logs that match the pattern hycu<device address> hycu: (serial:xxx) XID: <error code>, info: <description>, covering various faults in DCU hardware RAS (Reliability, Availability, and Serviceability) modules, temperature, drivers, and firmware. The same Condition/Event may correspond to multiple error codes:
Check Item
Detection Target
Detection Method
Trigger Condition
Corresponding Condition
DCU uncorrectable RAS error detection
Uncorrectable errors of each DCU hardware module (including memory controller, graphics engine, DMA controller, memory hub, interconnect bus, and others)
Parse XID error codes in DCU logs.
Detected any of XID 2, 4, 6, 8, 10, 12, 14, 16, 18, 30, and 82.
HygonDCUUncorrectableErr
DCU high temperature detection (logs)
DCU overtemperature
Parse XID error codes in DCU logs.
Detected either XID 50 or 301.
HygonDCUHighTemp
DCU isolation detection
DCU is actively isolated by the driver due to consecutive unrecoverable errors.
Parse XID error codes in DCU logs.
Detected XID 51.
HygonDCUIsolation
DCU device loss detection (logs)
DCU driver initialization failure
Parse XID error codes in DCU logs.
Detected XID 190.
HygonDCUDeviceLost
DCU PCIe link loss detection (logs)
PCIe link loss between the DCU and the host
Parse XID error codes in DCU logs.
Detected XID 160.
HygonDCUPCIeLinkLost
DCU driver error detection
DCU internal controller timeout, driver loading failure, microengine controller error, and graphics compute unit Harvest event
Parse XID error codes in DCU logs.
Detected any of XID 76, 77, 87, 112, and 124.
HygonDCUDriverError
DCU ECC page retirement detection
DCU video memory ECC page repair event and row remapping record failure
Parse XID error codes in DCU logs.
Detected either XID 120 or 122.
HygonDCUEccPageRetire
DCU high SBE error rate detection
Excessively high DCU single-bit ECC error rate (early warning of uncorrectable errors)
Parse XID error codes in DCU logs.
Detected XID 130.
HygonDCUHighSBERate
DCU virtual machine fault detection
A user-mode application illegally accesses DCU video memory.
Parse XID error codes in DCU logs.
Detected XID 81.
HygonDCUVMFault
DCU firmware error detection
DCU board VBIOS startup/loading failure and SMU firmware initialization exception
Parse XID error codes in DCU logs.
Detected any of XID 200, 201, and 300.
HygonDCUFirmwareError
DCU correctable RAS error detection
Correctable errors of each DCU hardware module
Parse XID error codes in DCU logs.
Detected any of XID 1, 3, 5, 7, 9, 11, 13, 15, 17, and 19.
None (only generates Event: DCUHasCorrectableRASError)
DCU MEC warning detection
DCU microengine controller warning, with a severity lower than that of a driver error.
Parse XID error codes in DCU logs.
Detected XID 111.
None (only generates Event: DCUMECWarning)
DCU other XID detection
New error codes not classified into any of the above categories
Parse XID error codes in DCU logs, and perform fallback capture when none of the above error code sets are matched.
Detected any DCU XID error code other than those listed above.
None (only generates Event: DCUHasOtherXidError)
Note:
The first 10 items are permanent rules. Once triggered, the corresponding Condition is set to True and retained for a long time. You must restart the NPD component to clear it. The last 3 items are temporary rules. They only generate one-time Events and are not reflected in node Conditions.
Hygon HySwitch SXID Log Detection:
dcuSxidMonitor parses records in Hygon logs that match the pattern hyfm: SXID: <error code> <description> (reported by HFM management tasks) or hsw<device address>: SXID: <error code> <description> (reported directly by HySwitch hardware), and uses these records to detect faults in the HySwitch interconnect chip and HFM (HySwitch Fabric Manager) management tasks in multi-DCU interconnect architectures. Such faults can make the DCU resources of the entire node unavailable:
Check Item
Detection Target
Detection Method
Trigger Condition
Corresponding Condition
HySwitch fatal error detection
HySwitch driver loading failures, register read timeouts, uncorrectable HSL link errors, internal control core faults, PCIe link loss, and faults detected by HFM tasks including driver loading failures, quantity mismatches, link establishment failures, reset failures, register read failures, DCU quantity mismatches, and VBIOS not supporting HSL
Parse SXID error codes in HySwitch/HFM logs.
Detected any of SXID 20, 200, 201, 204, 206, 207, 251, 253, 255, 257, 259, 261, 262, 263, 264, and 265.
HygonHySwitchError
HySwitch warning detection
HySwitch firmware update result notifications, firmware and driver version match verification results, and correctable HSL link errors
Parse SXID error codes in HySwitch/HFM logs.
Detected any of SXID 202, 203, and 205.
HygonHySwitchWarning
Detection of other HySwitch SXID errors
New error codes not classified into any of the above categories
Parse SXID error codes in HySwitch/HFM logs, and perform fallback capture when none of the above error code sets are matched.
Detected any SXID error code other than those listed above.
None (only generates Event: HySwitchOtherSXidError)
Note:
The fatal and warning categories are permanent rules. Once triggered, the corresponding Condition is set to True and retained for a long time. You must restart the NPD component to clear it. The fallback category is a temporary rule and only generates one-time Events. SXID 200 to 207 are reported directly by the HySwitch hardware, while SXID 20 and 251 to 265 are reported by HFM management tasks. Both share the same set of Conditions.

Appendix

Node Conditions

After the NPD plugin is installed, the following specific Conditions are added to the node:

System and Runtime Conditions

Condition Type
Default Value
Description
KernelDeadlock
False
Whether the kernel has a deadlock.
ReadonlyFilesystem
False
Whether the file system is read-only
DiskReadOnly
False
Whether the disk mount becomes read-only
XFSError
False
Whether XFS metadata I/O errors exist
FDPressure
False
Whether the number of host file descriptors reaches 80% of the maximum value
FDProblem
False
Whether file descriptors are abnormal
CustomPIDPressure
False
Whether the number of PIDs on the current node reaches 90% of the maximum value
ThreadPressure
False
Whether the number of system threads reaches 90% of the maximum value
ConntrackProblem
False
Whether conntrack table usage is abnormal
ProcessProblem
False
Whether the number of processes on the entire machine that remain in D state exceeds the threshold
SystemLoadProblem
False
Whether the system load is abnormal
MtuCacheProblem
False
Whether the MTU cache is abnormal
NetDeviceProblem
False
Whether the network device is abnormal
NetIpv4TcpTimeStampProblem
False
Whether the TCP timestamp setting is abnormal
FrequentUnregisterNetDevice
False
Whether the network device is frequently unregistered
NTPProblem
False
Whether the NTP time synchronization service is running normally
OverlayDiskPressure
False
Whether Overlay disk space is insufficient
StuckProcess
False
Whether a process has been in the D state for more than 120 seconds
StoppedProcess
False
Whether there are processes suspended by SIGSTOP (T state) for more than 120 seconds
CorruptDockerOverlay2
False
Whether Docker Overlay2 has a problem
ConnectApiServer
False
Whether the connection to API Server is normal
PLEGNotHealthy
False
Whether PLEG is healthy
KubeletRootDirMismatch
False
Whether existing Pods still mount volumes from the old path after the kubelet root-dir configuration is changed

Container Runtime and Kubelet Conditions

Condition Type
Default Value
Description
FrequentKubeletRestart
False
Whether Kubelet restarts more than 5 times within 20 minutes
FrequentDockerRestart
False
Whether Docker restarts more than 5 times within 20 minutes
FrequentContainerdRestart
False
Whether Containerd restarts more than 5 times within 20 minutes
KubeletProblem
False
Whether Kubelet service is Running
KubeletUnhealthy
False
Whether Kubelet health check is passed
DockerdProblem
False
Whether Docker service is Running (always False if the node runtime is Containerd)
ContainerdProblem
False
Whether Containerd service is Running (always False if the node runtime is Docker)
ContainerRuntimeUnhealthy
False
Whether the container runtime is healthy
ContainerRuntimeInterfaceUnhealthy
False
Whether the CRI interface is healthy
ContainerdRuntimeUnhealthy
False
Whether the Containerd runtime is healthy
HasGhostContainer
False
Whether ghost container processes exist

NVIDIA GPU Conditions

On nodes with NVIDIA GPUs, NPD registers the following Conditions:
Condition Type
Default Value
Description
GPUXIDFatalError
False
Whether the GPU has a fatal XID error.
GPUXIDWarningError
False
Whether the GPU has a warning-level XID error.
GPUDeviceLost
False
Whether the GPU device is lost or inaccessible
GPUDoubleBitEccError
False
Whether the GPU has a double-bit ECC error.
GPUHighSingleBitEccError
False
Whether the GPU single-bit ECC error rate exceeds the threshold.
GPUEccModeError
False
Whether the GPU ECC mode is abnormal (disabled or requires a restart to enable)
GPUTempError
False
Whether the GPU temperature exceeds the threshold.
GPUPowerError
False
Whether the GPU power cable has poor contact.
GPUPCIeError
False
Whether the GPU PCIe link is abnormal.
GPUNvlinkError
False
Whether the GPU NVLink is abnormal.
GPUInfoROMCorrupted
False
Whether the GPU InfoROM is corrupted.
GPUPendingRetiredPages
False
Whether the GPU has pages pending retirement.
GPURemappingRowsError
False
Whether the GPU row remapping has errors.

Hygon DCU Conditions

On nodes with Hygon DCU devices, NPD registers the following Conditions (the node must have the Hygon management tool hy-smi installed):
Condition Type
Default Value
Description
HygonDCUDeviceLost
False
DCU device loss or initialization failure
HygonDCUHighTemp
False
DCU overtemperature
HygonDCUUncorrectableErr
False
DCU uncorrectable RAS error
HygonDCUIsolation
False
DCU device isolated.
HygonDCUPCIeLinkLost
False
DCU PCIe link loss
HygonDCUDriverError
False
DCU driver or firmware error
HygonDCUHighSBERate
False
Excessively high DCU single-bit ECC error rate
HygonDCUEccPageRetire
False
DCU ECC page retirement
HygonDCUVMFault
False
DCU virtual machine fault
HygonDCUFirmwareError
False
DCU firmware error (detected through XID)
HygonHySwitchError
False
Critical HySwitch switch chip error (detected through SXID)
HygonHySwitchWarning
False
HySwitch switch chip warning (detected through SXID)

NVIDIA GPU XID Error Code Meanings

The following are the specific meanings of each NVIDIA GPU XID error code detected by xidMonitor. For detection rules and corresponding Conditions/Events, see "Detection Item Description - GPU (NVIDIA) Hardware Detection".
XID
Category
Meaning
13
Warning / Application-level
Graphics Engine Exception, commonly caused by applications accessing video memory out of bounds.
31
Warning / Application-level
GPU memory page fault, usually caused by out-of-bounds access by applications.
43
Warning / Application-level
GPU stopped processing, often accompanied by driver or application crashes.
45
Warning / Application-level
Preemptive cleanup triggered by preceding errors, usually a secondary phenomenon accompanying other error codes.
48
Warning
Memory double-bit uncorrectable ECC error, a hardware-level critical issue.
62
Warning
The internal GPU microcontroller stops running.
63
Warning / Application-level
ECC page retirement or row remapping record event (not yet failed)
64
Application-level
ECC page retirement or row remapping record failure, with higher severity than error code 63.
68
Warning / Application-level
Video decoder engine (NVDEC) exception
74
Critical.
NVLink error, commonly seen in multi-GPU high-speed interconnect training scenarios.
79
Fatal
GPU falls off the PCIe bus, indicating a hardware-level critical fault.
92
Warning
Single-bit ECC error rate is excessively high, serving as an early warning signal.
94
Warning / Application-level
Controlled ECC error isolation triggered after row remapping failure
95
Warning
Uncontrollable ECC error, where the fault may have propagated and affected the correctness of computation results.
109
Warning
Context Switch Timeout
110
Warning
Security fault, such as video memory encryption or trust zone exception
119
Warning
GPU system processor (GSP) RPC call timeout, usually caused by driver or firmware communication exceptions.
120
Warning
Internal GSP firmware error
122
Warning
Firmware SPI bus read failure
123
Warning
Firmware SPI bus write failure
124
Warning
Firmware SPI bus erase failure
137
Warning
Uncorrectable NVLink error
140
Warning
Unrecovered ECC error
141
Ignored.
Known benign event that does not generate any alarms.
Note:
Error codes 13, 31, 43, 45, 63, 68, and 94 belong to both the warning and application-level categories. When triggered, they generate a one-time Event and set the corresponding warning Condition to True. Error code 64 belongs only to the application-level category. It only generates an Event and does not affect node Conditions. Other error codes not listed are uniformly classified into the fallback category. They only generate one-time Events to detect newly emerging unclassified fault codes.

Hygon DCU XID Error Code Meanings

The following are the specific meanings of each Hygon DCU XID error code detected by dcuXidMonitor. For detection rules and corresponding Conditions/Events, see "Detection Item Description - Hygon DCU Hardware Detection".
XID
Severity Level
Meaning
1,3,5,7,9,11,13,15,17,19
Monitor only
Correctable errors of each DCU hardware module (including memory controller, graphics engine, DMA controller, memory hub, interconnect bus, and others)
2,4,6,8,10,12,14,16,18,30,82
Critical.
Uncorrectable errors of each DCU hardware module. Computation results may have been affected.
50
Critical.
DCU overtemperature
51
Critical
DCU is actively isolated by the driver due to consecutive unrecoverable errors.
160
Fatal
PCIe link loss between the DCU and the host
190
Critical.
DCU driver initialization failure
200,201
Fatal
DCU board VBIOS startup or loading failure
300
Critical
DCU SMU firmware initialization exception
76,77
Critical
Operation timeout of the DCU internal controller (QCM/HDP)
87
Critical
DCU driver loading failure
112
Critical
DCU microengine controller (MEC) error
124
Critical
DCU graphics compute unit Harvest event
81
Critical
DCU virtual machine fault, usually caused by user-mode applications illegally accessing video memory. Restart the related service to clear the fault.
111
Warning
DCU microengine controller (MEC) warning, with a severity lower than that of error code 112
120
Warning
DCU video memory ECC page repair event (self-healing mechanism activated)
122
Warning
DCU video memory row remapping record failure, with a severity higher than that of error code 120
130
Warning
Excessively high DCU single-bit ECC error rate, serving as an early warning of uncorrectable errors.
301
Warning
DCU critical temperature warning
Note:
Other DCU XID error codes not listed are uniformly classified into the fallback category. They only generate one-time Events to detect newly emerging unclassified fault codes.

Hygon HySwitch SXID Error Code Meanings

The following are the specific meanings of each Hygon HySwitch SXID error code detected by dcuSxidMonitor. For detection rules and corresponding Conditions/Events, see "Detection Item Description - Hygon DCU Hardware Detection".
SXID
Severity Level
Meaning
20,200
Critical.
HySwitch driver loading failure
201
Critical.
Timeout when HySwitch registers are read
204
Critical.
An uncorrectable error occurs on the HSL interconnect link.
206
Critical
HySwitch internal control core fault
207
Fatal
HySwitch chip PCIe link loss
202
Warning
HySwitch firmware update result notification
203
Warning
HySwitch firmware and driver version match verification result
205
Warning
A correctable error occurs on the HSL interconnect link.
251
Critical
The HFM task detects a HySwitch driver loading failure.
253
Critical.
The HFM task detects a mismatch between the number of HySwitches and the configuration.
255
Fatal
The HFM task detects a HySwitch link establishment failure.
257
Critical.
The HFM task detects a HySwitch reset failure.
259
Critical.
The HFM task fails to reset the DCU when no DCU driver is present.
261
Critical.
The HFM task detects that the number of system resets has reached the upper limit.
262
Critical.
The HFM task fails to read DCU registers, which may indicate a risk of card removal.
263
Critical.
The HFM task fails to read the number of DCUs or HySwitches.
264
Critical.
The HFM task detects that the number of DCUs does not match the expected value.
265
Critical.
The HFM task detects that the VBIOS of some DCUs does not support HSL interconnect.
Note:
SXID 200 to 207 are reported directly by the HySwitch hardware, while SXID 20 and 251 to 265 are reported by HFM management tasks. Both share the same set of Conditions. Other SXID error codes not listed are uniformly classified into the fallback category and only generate one-time Events.